You are here: Home > Venue Information > Cliffs Pavilion - Venue Specific > Technical Specification
Technical Specification
Digs List
The accommodation list is available from the administration office on request.
Stage and Events Team
The Stage and Events Team comprises of seven full time members of staff and a team of casuals. The full time members of staff are:-
Stage and Technical Manager: Chris Lawman
Technician/Head of Sound: Glenn Oxenbury
Technician: Darren Wilson
Technician: Glen Witherall
Technician: Brian Warrens
Technician: Michael Lewin
Technician: Chris Lowe
The Stage
A 1:25 ground plan of the Cliffs Pavilion is available from 'Modelbox' 0183754026
GENERAL STAGE INFORMATION
|
Stage Height |
1.09m (3'7) |
|
Stage Rake |
1 To 25 |
|
Proscenium Width |
9.92m to 14.17m |
|
Proscenium Height |
5.33m (17'6) |
|
Stage Depth |
9.5m (OP) |
|
|
9.53m (PS) |
|
Height to Grid |
11.62m |
|
Scenery Flying Height |
5.3m (17'6') |
|
Height to Fly Floor |
6.4m (21') |
|
Clear to |
5.85m (19'6) |
|
Control Room to Stage Front |
25.45m (83'6') |
GENERAL STAGE EQUIPMENT
The Venue has a selection of:-
Stage braces of varying sizes
20 Stage Weights
Various lengths of conduit
ROSTRA
22 Merricks Sico Wheeled Rostra:-
|
Surface Area |
2.4m x 1.2m (8'x4') |
|
Height |
8 x 45cm (19') |
|
|
4 x 60cm (2') |
|
|
4 x 75cm (2'6') |
|
|
6 x 90cm (3') |
FLYING
|
Flying Height |
Scenery |
5.3m (17'6) |
|
Flying Height |
to Fly Floor |
6.4m (21') |
|
|
clear to |
5.85m (19'6') |
|
Flying Lines |
counterweight |
27 Sets |
|
Weight Capacity per cradle |
|
400Kg (873lb) |
|
SWL per bar Inc bar weight |
|
340kg |
|
Flying Bar Lengths |
|
16.45m (54') |
|
At |
|
23cm centres |
Masking
The venue has:-
One set of black masking, comprising of:-
1 x set of full black tabs 18 ft high
1 x set of full black tabs 25 ft high
3 x 2 metre high black borders
5 x 15 ft black borders
8 x 2 metre wide black legs
8 x 12 ft wide x 25 ft high black legs
1 x Set of scarlet and gold house tabs.
All Bars are on a single purchase counterweight
|
Edge of stage |
|
0m |
|
Safety Curtain |
|
1.98m |
|
Setting Line |
(with no house tabs) |
2.0m |
|
1 |
(house tabs) |
2.36m |
|
2 |
(Setting line with house tabs) |
2.59m |
|
3 |
|
2.82m |
|
4 |
|
3.05m |
|
5 |
|
3.28m |
|
6 |
|
3.5m |
|
7 |
|
3.73m |
|
8 |
|
3.96m |
|
9 |
|
4.19m |
|
10 |
|
4.65m |
|
11 |
|
4.88m |
|
12 |
|
5.1m |
|
13 |
|
5.33m |
|
14 |
|
5.56m |
|
15 |
|
5.79m |
|
16 |
|
6.02m |
|
17 |
|
6.25m |
|
18 |
|
6.48m |
|
19 |
|
6.71m |
|
20 |
|
6.93m |
|
21 |
|
7.39m |
|
22 |
|
7.62m |
|
23 |
|
7.85m |
|
24 |
|
8.3m |
|
25 |
|
8.53m |
|
26 |
|
8.76m |
|
Hemp 1 |
|
|
|
Hemp 2 |
|
|
|
Back Wall |
|
9.75m |
Visiting Power
VISITING LIGHTING SUPPLY
The visiting lighting power is situated down stage right.
The supply is 400 amp, 3 phase.
The distribution outlets are as follows:-
|
Type |
Phase |
Number |
|
15 amp |
1 |
2 |
|
16 amp Ceeform |
1 |
6 |
|
32 amp Ceeform |
3 |
1 |
|
63 amp Ceeform |
1 |
1 |
|
63 amp Ceeform |
3 |
1 |
|
125 amp Ceeform |
3 |
1 |
|
200 amp Power locks |
3 |
1 set |
|
400 amp Power locks |
3 |
1 set |
The venue has one set of Power lock to Cam Lock jumpers.
VISITING SOUND SUPPLY
The visiting sound supply is situated up stage right. The supply is 100 amp, 3 phase. The distribution outlets are as follows: -
|
Type |
Phase |
Number |
|
32 amp Ceeform |
1 |
1 |
|
63 amp Ceeform |
1 |
1 |
|
63 amp Ceeform |
3 |
1 |
LOADING BAY SUPPLY
Situated in the loading bay the supply is 200 amps, 3 phase The distribution outlets are as follows: -
|
Type |
Phase |
Number |
|
13 amp |
1 |
8 |
|
15 amp |
1 |
2 |
|
16 amp Ceeform |
1 |
2 |
|
63 amp Ceeform |
1 |
1 |
|
200 amp Power locks |
3 |
1 set |
Luminaries List
PROFILES
|
Type |
Number |
|
E.T.C Source 4 25 / 50 575w / 750w |
8 |
|
E.T.C Source 4 Zooms 15 /30 750w |
18 |
|
E.T.C Source 4 19 750w |
2 |
|
E.T.C Source 4 36 750w |
6 |
|
E.T.C Source 4 50 750w |
1 |
|
E.T.C Source 4 Lens Tube 5 |
2 |
|
E.T.C Source 4 Lens Tube 10 |
1 |
FRESNELS
|
Type |
Number |
|
C.C.T Starlette 1k No barn doors |
10 |
|
Stand cantata F 1k With barn doors |
24 |
|
Strand2k F Alto With barn doors |
3 |
FLOODS AND PAR CANS
|
Type |
Number |
|
Thomas Par 64 CP62 |
50 |
|
Thomas Floor Can CP62 |
4 |
|
Rank
|
10 |
|
Coda 4s 500w |
6 |
FOLLOW SPOTS
The venue has two Pani 1202 follow spots situated on bridge three.
Please contact us nearer to your visit to confirm luminaries' availability.
FRONT OF HOUSE LIGHTING POSITIONS
|
Bridge 1 |
Front of Stage to Below Bridge 1 |
3.8m |
|
|
Throw to Setting Line |
9.5m |
|
|
(Please note bridge 1 is not a good position to cover mid to up stage)
|
|
|
Bridge 2 |
Front of Stage to Below Bridge 2 |
7.9m |
|
|
Throw to Setting Line |
13m |
|
Bridge 3 (Follow Spot Position)
|
Front of Stage to Below Bridge 3 |
12.2m |
|
|
Throw to Setting Line |
16.5m |
|
Frnt.Boxes |
Front Stage to Front
|
3.7m |
|
|
Throw to Setting Line |
6.8m |
|
Auditorium Perches left and right
|
|
|
|
Balcony |
Balcony to Front Stage |
20.7m
|
|
|
Throw to Setting Line |
25.0m |






ShareThis